DSTU2

This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Obs-uslab-example4.xml

Raw XML (canonical form)

USLab Ratio Observation Profile Example: Dengue Titer (id = "obs-uslab-example4")

<Observation xmlns="http://hl7.org/fhir">
  <id value="obs-uslab-example4"/>
<!--     FHIR build is generating the narratives
<text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
      <ul>
        <li> obs-uslab-example4.xml</li>
        <li> id: uslab-example4</li>
        <li> Name: USLab Observation Example4</li>
        <li>Description: USLab Ratio Observation Profile Canonical Example: Dengue Virus</li>
      </ul>
    </div>
  </text>
    -->
<!--     extension for specimen reject goes here - not for this use case
  <extension url="http://hl7.org/fhir/StructureDefinition/uslab-specimenrejectreason">
    <valueCodeableConcept>
      <coding>
        <system value="http://hl7.org/fhir/v2/0490"/>
        <code value="EX"/>
        <display value="Expired"/>
      </coding>
    </valueCodeableConcept>
  </extension>
    -->
<!--     extension for observation kindt goes here     -->
  <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: obs-uslab-example4</p><p><b>identifier</b>: lab test result ID = 4567 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Dengue IgM Titer <span>(Details : {LOINC code '6812-2' = 'Dengue virus IgM Ab [Titer] in Serum', given as 'Dengue
           virus IgM Ab [Titer] in Serum'}; {urn:oid:2.16.840.1.113883.3.72.5.24 code 'DGIGM' = '??',
           given as 'Dengue IgM QN'})</span></p><p><b>subject</b>: <a>Todd Lerr</a></p><p><b>effective</b>: 05/12/2014</p><p><b>issued</b>: 06/12/2014 3:42:15 PM</p><p><b>performer</b>: <a>Dr Leonard T Bloodraw Jr</a></p><p><b>value</b>: 1/256</p><p><b>interpretation</b>: High <span>(Details : {http://hl7.org/fhir/v2/0078 code 'H' = 'High)</span></p><p><b>specimen</b>: <a>Bloo sample</a></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Text</b></td></tr><tr><td>*</td><td>&lt;1:64</td></tr></table></div></text><extension url="http://hl7.org/fhir/StructureDefinition/uslab-observationkind">
    <valueCode value="result"/>
  </extension>
  <identifier>
    <use value="official"/>
    <type>
      <text value="lab test result ID"/>
    </type>
    <system value="http://lis.acmelabs.org/identifiers/labtestresult"/>
    <value value="4567"/>
  </identifier>
  <status value="final"/>
<!--    EH :  The local and /or LOINC test codes go here     -->
  <code>
  <!--     EH: LOINC code goes here    -->
    <coding>
      <system value="http://loinc.org"/>
      <code value="6812-2"/>
      <display value="Dengue virus IgM Ab [Titer] in Serum"/>
    <!--     EH: LOINC code goes here    -->
    </coding>
    <coding>
      <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/>
      <code value="DGIGM"/>
      <display value="Dengue IgM QN"/>
    </coding>
    <text value="Dengue IgM Titer"/>
  </code>
  <subject>
    <reference value="Patient/patient-uslab-example1"/>
    <display value="Todd Lerr"/>
  </subject>
  <effectiveDateTime value="2014-12-05"/>
<!--     EH: Showing dateTime to ss with TZO although only needed to Day     -->
  <issued value="2014-12-06T15:42:15-08:00"/>
  <performer>
    <reference value="Practitioner/pract-uslab-example1"/>
    <display value="Dr Leonard T Bloodraw Jr"/>
  </performer>
<!--     In FHIR, units may be represented twice. Once in the
    agreed human representation, and once in a coded form.
    Both is best, since it's not always possible to infer
    one from the other in code.

    When a computable unit is provided, UCUM (http://unitsofmeasure.org)
    is always preferred, but it doesn't provide notional units (such as
    "tablet"), etc. For these, something else is required (e.g. Snomed-CT)
       -->
  <valueRatio>
    <numerator>
      <value value="1"/>
    </numerator>
    <denominator>
      <value value="256"/>
    </denominator>
  </valueRatio>
<!--      eH dataabsent reason  would go here if valueQuantity was empty e.g.:
  <dataAbsentReason value="error"/>     -->
  <interpretation>
    <coding>
      <system value="http://hl7.org/fhir/v2/0078"/>
      <code value="H"/>
    </coding>
  </interpretation>
  <specimen>
    <reference value="Specimen/spec-uslab-example1"/>
    <display value="Bloo sample"/>
  </specimen>
  <referenceRange>
    <text value="&lt;1:64"/>
  </referenceRange>
</Observation>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.